Theoretical weight is computed via D² / 162. Ensure purchased bars meet certified standard tolerance standards (e.g. SNI).

Compare options

Scenario comparison

Save up to three input combinations and compare their results. Scenarios stay in this browser.

Change the inputs, then save your first scenario to start comparing.

Quick guide

How to interpret results.

Divides total continuous bar length by standard 12-meter commercial lengths, applies overlap/waste factors, and calculates theoretical steel weight using D² / 162 kg/m.

  1. 01

    Enter total linear meters of required reinforcement including lap splices.

  2. 02

    Select bar nominal diameter in millimeters (e.g. 8, 10, 12, 16 mm).

  3. 03

    Specify unit price per bar or per kilogram to estimate procurement budget.

Engineering considerations

  • Standard commercial rebar length in Indonesia and most metric regions is 12.0 meters.
  • Lap splices (typically 40× diameter) and hook bends must be included in total linear meters.
  • Always inspect for standardized certification markings (e.g. SNI) to avoid undersized 'banci' bars.

Frequently asked questions

Answers to common questions.

What is the formula for rebar theoretical weight?

Weight (kg/m) = Diameter² / 162. For example, a 10 mm bar weighs 100/162 ≈ 0.617 kg per meter.

How long is a commercial rebar stick?

Standard deformed and plain round bars are manufactured in 12-meter lengths.

What is an overlap splice?

Where two bars meet, they must overlap by approximately 40 times their diameter (e.g. 40 cm for 10 mm rebar) to transfer tension loads.